Alphabetical Index
Keyword Search
Casting Defects
Ingot Defects
Slab Defects
Drawing Defects
Forging Defects
Rolling Defects
Bearing Defects
Coating Defects
Corrosion Defects
Fractography
Heat Treatment Defects
Machining Defects
Other Defects
Pipeline Defects
Polishing Defects
Rail Defects
Tool Steel Defects
Welding Defects
Internal Defects
Surface Defects
Internal + Surface Defects
Contact Us
Help
Home
Vibration I - Gear defects - Other defects
Figure 1: Sheared synchronizer pins are a sign of
vibration.
Defect name: Vibration
Record No.: 2146
Type of defect (Internal/Surface): Surface
Defect classification: Gear defects, other defects
Steel name: Steel
Steel composition in weight %: No data.
Note: Vibration is another big cause of synchronizer
failures. Broken or sheared synchronizer pins are
a very common sign of vibration, see Figure 1.
The brass synchronizer ring may also be pushed
off the pins due to vibration, see Figure 1.
Reference: Not shown in this demonstration version.